Fact Sheet
Self Cleaning suction filters and strainers
 |
 |
 |
 |
 |
 |
 |
| |
02008-16 Filterpumps
Submersible pump with an integral self cleaning intake filter.
These pumps have a maximum output of 220 litres/minute and pressure of 7.4 bar.
They are fitted with a standard 300 micron aperture self cleaning filter screen.
The pumps can work in fluids containingup to 2000mg/litre total suspended solids(raw sewage typically 500-1000 mg/l TSS)
They produce a filtered output of fluid which prevents blockage to nozzles, valves and solenoids.
|
|
02008-16
220 litres/minute
|
|
|
|
| |
|
|
Screen apertures - 315, 250, 100 & 50 Micron (300 Micron = 0.3mm) |
|
 |
 |
 |
 |
| |
|
|
|
| |
The Rotorflush 02008-16 is made entirely of AISI 304 stainless steel. Cooling of the motor is via a heat exchange chamber that allows the pump to work for long periods when not completely submerged.
Design Features
Stainless Steel pump casing
Stainless steel self-cleaning inlet filter (standard Filter screen 300 microns)
Cast stainless Steel impellers
10metres H07 RN-F power supply cable with plug
Fixed double NBR 70 rubber seal
Oil chamber for seal lubrication
Stainless seal shaft with a ceramic facing at the points of seal wear
Supplied with float level switch in the AUTOMATIC versions
Suitable for continuous use
Motor
Dry motor with stainless steel casing
Level of protection IP68
Class F insulation
Single-phase power supply 50 Hz (230V or 110V) permanently activated
Thermal protection built into motor winding
Completely insulated cable connection chamber
Self lubricating ball bearings
Speed of rotation 2850 rpm
Usage limitations
Type of liquid: water with suspended solids
Maximum liquid temperature 40C
Maximum submersion depth 7 metres
Minimum Water Depth 250mm
Dimensions: Height 500mm, Diameter 200mm |
|
|
| |
|
|
|
 |
 |
 |
 |
| |
|
|
|
| |
Typical Applications
Pumping and filtering of water containing suspended solids
Water re-use by installing the Filterpump in a tank liquid is removed leaving solids greater than screen apertures behind
Use where other pumps block by ingesting rag etc
Use to prevent valves and nozzles being blocked by solids in the water. |
|
|
| |
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| |
Model |
 |
Volts |
 |
kW |
 |
Outlet |
|
L/min
Max |
|
H (metres)
Max |
|
Float Switch |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| |
2008-16 Man. |
 |
220/240 |
 |
0.5 |
 |
1 1/4" |
|
200 |
|
8 |
|
No |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| |
02008-16 Auto |
 |
220/240 |
 |
0.5 |
 |
1 1/4" |
|
200 |
|
8 |
|
Yes |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| |
Also Available in 110 Volts |
|
|
| |
|